Cross-section of standard configuration
[Additional views]
Remark:
Attention: Composite component (A + wood wool board + DF) self-supporting as wall covering.
last update21.03.2013/hfa.plb
|
Data sheet
compartment wall: solid wood construction, without dry lining
Performance rating
| Fire protection performance |
REI |
90 |
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m Classified by MA39
|
| Thermal performance |
U [W/m²K] |
0,23 |
| Diffusion adequate |
adequate |
| mw,B,A [kg/m²] |
19,7 |
Calculated by HFA
|
| Acoustic performance |
Rw (C;Ctr) |
63 (;) |
| Ln,w
(Cl) |
– |
B= s'<13 Assessed by TU-GRAZ
|
| Sustainability* |
OI3Kon |
11,4 |
Calculated by IBO
|
|
 |
 |
|
| |
Register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)
| |
Thickness |
Building material |
λ |
μ min - max |
ρ |
c |
Reaction to fire |
| EN |
| A |
62,5 |
wood wool composite boards
composite member with plasterboard lining on both faces (eternal: 15 mm DF, internal: 12.5 mm A) |
0,090 |
2 - 5 |
370 |
2,000 |
B |
| B |
50,0 |
impact sound absorbing subflooring MW-T
|
0,036 |
1 |
100 |
1,030 |
A1 |
| C |
125,0 |
solid wood
(e.g. cross laminated timber) |
0,130 |
50 |
500 |
1,600 |
D |
| D |
25,0 |
impact sound absorbing subflooring MW-T
|
0,036 |
1 |
100 |
1,030 |
A1 |
| E |
62,5 |
wood wool composite boards
composite member with plasterboard lining on both faces (eternal: 15 mm DF, internal: 12.5 mm A) |
0,090 |
2 - 5 |
370 |
2,000 |
B |
* Details of sustainability rating
* Mass per unit area
m
[kg/m²] |
calculation based on |
| 135,4 |
gypsum plasterboard (DF) |
|