Building components- external wall - awropo03b-00
 
 


Cross-section of standard configuration
[Additional views]

last update10.07.2014/hfa.plb
Data sheet

external wall: timber frame construction, not ventilated, without dry lining, with rendering


Performance rating

Fire protection performance  REI 60 
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by MA39
 
Thermal performance U [W/(m²K)] 0,20 
Diffusion adequate 
mw,B,A [kg/m²] 35,5 
Calculated by HFA
 
Acoustic performance Rw (C;Ctr)   49 (-2;-7)
Ln,w (Cl)  – 
Assessed by MA39
 
Sustainability* OI3Kon 16,7 
Calculated by IBO
 
   
  Register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 7,0 plaster   1,000  10 - 35  2000  1,130   A1
 60,0 wood-fibre insulation board   0,055  5 - 7  200  2,100   E
 160,0 finger-jointed solid construction timber (60/..; e=625)  0,130  50  500  1,600   D
 160,0 glass wool [0,0040; R=16]   0,040  16  1,030   A1
 19,0 particleboard   0,130  50 - 100  700  1,700   D
  vapour barrier sd≥ 2m       1000     
 15,0 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 15,0 gypsum fibre board   0,320  21  1000  1,100   A2


* Details of sustainability rating

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-19,3 0,223 798,6 726,1 0,026 0,013


* Mass per unit area

m
[kg/m²]
calculation based on
66,9 gypsum plasterboard (DF)