Cross-section of standard configuration
[Additional views]
Last update21.03.2013/hfa.plb |
compartment floor: timber frame construction, suspended, wet
register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)
| |
Thickness |
Building material |
λ |
μ min - max |
ρ |
c |
Reaction to fire |
| EN |
| A |
50.0 |
cement screed
or anhydrite screed |
1,330 |
50 - 100 |
2000 |
1,080 |
A1 |
| B |
|
plastic separation layer
|
0,200 |
100000 |
1400 |
1,400 |
E |
| C |
* |
Exchangeable layer |
|
|
|
|
|
| D |
40.0 |
fill
|
0,700 |
2 |
1800 |
1,000 |
A1 |
| E |
|
trickling protection
|
|
|
|
|
E |
| F |
19.0 |
particleboard
|
0,130 |
50 - 100 |
700 |
1,700 |
D |
| G |
* |
finger-jointed solid construction timber
(80/..; e=*) |
0,130 |
50 |
500 |
1,600 |
D |
| H |
* |
Insulation material |
|
|
|
|
|
| I |
24.0 |
spruce wood
cladding with spacing of cladding boards(24/100); a=400 |
0,130 |
50 |
500 |
1,600 |
D |
| J |
27.0 |
resilient channel
placed between cladding with spacing |
|
|
|
|
|
| K |
25.0 |
gypsum plasterboards with improved properties at high temperatures (fire)
(2x12,5 mm) or |
0,250 |
10 |
800 |
1,050 |
A2 |
| K |
25.0 |
gypsum fibre board
(2x12,5 mm) |
0,320 |
21 |
1000 |
1,100 |
A2 |
|
 |
 |
|
| |
Variations of building components
| No. |
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
HTML | PDF |
| |
C* |
G* |
H* |
Σ |
|
REI |
U [W/m²K] |
mw,B,A [kg/m²] |
Diffusion |
Ln,w(Cl) |
Rw(C,Ctr) |
OI3Kon |
m [kg/m²] |
| |
| 00 |
30 |
220 |
100 |
411,0 |
e=625; C=impact sound absorbing subflooring MW-T |
60 |
0,26 |
26,1 |
adequate |
41(0) |
70(0,-4) |
12,3 |
226,0 |
tdrnxa03b-00 |
|
| H = glass wool [0,0040; R=16] |
| 01 |
30 |
200 |
100 |
391,0 |
e=625; C=impact sound absorbing subflooring MW-T |
60 |
0,26 |
26,1 |
adequate |
41(1) |
70(0,-5) |
12,3 |
224,7 |
tdrnxa03b-01 |
|
| H = glass wool [0,0040; R=16] |
| 02 |
30 |
240 |
100 |
431,0 |
e=625; C=impact sound absorbing subflooring MW-T |
60 |
0,26 |
26,1 |
adequate |
40(1) |
71(0,-5) |
18,2 |
227,3 |
tdrnxa03b-02 |
|
| H = glass wool [0,0040; R=16] |
| 03 |
30 |
220 |
100 |
411,0 |
e=625; C=impact sound absorbing subflooring MW-T |
60 |
0,24 |
26,4 |
adequate |
41(0) |
70(0,-4) |
24,7 |
229,3 |
tdrnxa03b-03 |
|
| H = glass wool [0,0035; R=50] |
| 04 |
30 |
220 |
100 |
411,0 |
e=625; C=impact sound absorbing subflooring MW-T |
60 |
0,26 |
26,1 |
adequate |
41(0) |
70(0,-4) |
22,0 |
227,5 |
tdrnxa03b-04 |
|
| H = mineral wool [0,038; R=33] |
| 05 |
30 |
220 |
100 |
411,0 |
e=625; C=impact sound absorbing subflooring MW-T |
60 |
0,26 |
26,1 |
adequate |
41(0) |
70(0,-5) |
8,2 |
229,4 |
tdrnxa03b-05 |
|
| H = cellulose fibre [040; E] |
| 06 |
30 |
220 |
100 |
411,0 |
e=625; C=impact sound absorbing subflooring MW-T |
60 |
0,27 |
26,2 |
adequate |
41(0) |
70(-1,-6) |
8,0 |
226,0 |
tdrnxa03b-06 |
|
| H = sheep wool [0,041; R=16] |
| 07 |
30 |
220 |
100 |
411,0 |
e=625; C=impact sound absorbing subflooring EPS-T |
60 |
0,27 |
26,1 |
adequate |
43(1) |
70(-1,-6) |
6,1 |
224,3 |
tdrnxa03b-07 |
|
| H = glass wool [0,0040; R=16] |
| 08 |
30 |
220 |
100 |
411,0 |
e=400; C=impact sound absorbing subflooring MW-T |
60 |
0,27 |
27,2 |
adequate |
48(1) |
67(-1,-6) |
12,3 |
233,8 |
tdrnxa03b-08 |
|
| H = glass wool [0,0040; R=16] |
| 09 |
30 |
220 |
100 |
411,0 |
e=625; C=Polystyrene EPS-W [0,041] |
60 |
0,27 |
26,1 |
adequate |
50(1) |
65(-2,-7) |
10,1 |
224,4 |
tdrnxa03b-09 |
|
| H = glass wool [0,0040; R=16] |
|