Building components- external wall - awropi12a
 
 


Cross-section of standard configuration
[Additional views]

Last update08.09.2014/hfa.plb
external wall: timber frame construction, not ventilated, with dry lining, with rendering

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 4.0 plaster   1,000  10 - 35  2000  1,130   A1
 50.0 wood wool composite boards   0,090  2 - 5  370  2,000   B
 12.0 OSB   0,130  200  650  1,700   D
*   finger-jointed solid construction timber (60/..; e=*)  0,130  50  500  1,600   D
*   Insulation material            
 15.0 OSB   0,130  200  650  1,700   D
  vapour barrier sd≥ 13m       1000     
*   spruce wood cross battens (a=400) or battens offset)  0,130  50  500  1,600   D
*   Exchangeable layer          
 12.5 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  D* E* H* I* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   160  160  40  40  293,5  e=625
I=glass wool [0,0040; R=16] 
60  0,19  19,8  adequate  –  52(-3,-8)  8,8  64,6   awropi12a-00  
E/I = glass wool [0,0040; R=16]
01   120  120  40  40  253,5  e=625
I=glass wool [0,0040; R=16] 
60  0,23  19,6  adequate  –  51(-3,-8)  6,3  62,0   awropi12a-01  
E/I = glass wool [0,0040; R=16]
02   160  160  40    293,5  e=625 ; I=without insulation
I=air layer 
60  0,22  28,6  adequate  –  51(-3,-8)  6,6  64,0   awropi12a-02  
E = glass wool [0,0040; R=16]
03   200  200  40  40  333,5  e=625
I=glass wool [0,0040; R=16] 
60  0,16  19,9  adequate  –  53(-3,-8)  11,3  67,0   awropi12a-03  
E/I = glass wool [0,0040; R=16]
04   240  240  40  40  373,5  e=625
I=glass wool [0,0040; R=16] 
60  0,15  20,0  adequate  –  54(-3,-8)  13,9  69,5   awropi12a-04  
E/I = glass wool [0,0040; R=16]
05   200  200  80  80  373,5  e=625
I=glass wool [0,0040; R=16] 
60  0,14  16,5  adequate  –  53(-3,-8)  13,6  70,1   awropi12a-05  
E/I = glass wool [0,0040; R=16]
06   240  240  80  80  413,5  e=625
I=glass wool [0,0040; R=16] 
60  0,13  16,6  adequate  –  54(-3,-8)  16,1  72,6   awropi12a-06  
E/I = glass wool [0,0040; R=16]
07   160  160  40  40  293,5  e=625
I=glass wool [0,0035; R=50] 
60  0,18  19,1  adequate  –  53(-3,-8)  34,2  70,6   awropi12a-07  
E/I = glass wool [0,0035; R=50]
08   160  160  40  40  293,5  e=625
I=mineral wool [0,038; R=33] 
60  0,19  19,8  adequate  –  52(-3,-8)  21,1  67,6   awropi12a-08  
E/I = mineral wool [0,038; R=33]
09   160  160  40  40  293,5  e=625
I=cellulose fibre [040; E] 
60  0,18  19,8  adequate  –  52(-3,-8)  2,2  67,0   awropi12a-09  
E = cellulose fibre [0,040; R=55]
10   160  160  40  40  293,5  e=625
I=sheep wool [0,041; R=26] 
60  0,21  20,4  adequate  –  52(-3,-8)  -0,0  64,5   awropi12a-10  
E/I = sheep wool [0,041; R=26]
11   160  160  40  40  293,5  e=400
I=glass wool [0,0040; R=16] 
60  0,20  19,7  adequate  –  52(-3,-8)  8,5  68,7   awropi12a-11  
E/I = glass wool [0,0040; R=16]