Building components- external wall - awropi10b
 
 


Cross-section of standard configuration
[Additional views]

Last update08.05.2013/hfa.plb
external wall: timber frame construction, not ventilated, with dry lining, with rendering

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 4.0 plaster   1,000  10 - 35  2000  1,130   A1
 50.0 wood wool composite boards   0,090  2 - 5  370  2,000   B
 10.0 gypsum fibre board   0,320  21  1000  1,100   A2
*   finger-jointed solid construction timber (60/..; e=*)  0,130  50  500  1,600   D
*   Insulation material            
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
  vapour barrier sd≥ 4m       1000     
*   spruce wood cross battens (a=400) or battens offset)  0,130  50  500  1,600   D
*   Insulation materialor air layer in type 02            
 12.5 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  D* E* H* I* Σ   REI U [W/m²K] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   160  160  40  40  289,0  e=625
 
60  0,20  19,5  adequate  –  52(-3,-8)  -0,3  69,5   awropi10b-00  
E/I = glass wool [0,0040; R=16]
01   120  120  40  40  249,0  e=625
 
60  0,24  19,3  adequate  –  51(-3,-8)  -2,9  67,0   awropi10b-01  
E/I = glass wool [0,0040; R=16]
02   160  160  40    289,0  e=625 ; I=without insulation
 
60  0,23  27,1  adequate  –  51(-3,-8)  -2,6  69,0   awropi10b-02  
E = glass wool [0,0040; R=16]
03   200  200  40  40  329,0  e=625
 
60  0,17  19,7  adequate  –  53(-3,-8)  2,2  72,0   awropi10b-03  
E/I = glass wool [0,0040; R=16]
04   240  240  40  40  369,0  e=625
 
60  0,15  19,8  adequate  –  54(-3,-8)  4,7  74,5   awropi10b-04  
E/I = glass wool [0,0040; R=16]
05   200  200  80  80  369,0  e=625
 
60  0,15  16,6  adequate  –  53(-3,-8)  4,4  75,1   awropi10b-05  
E/I = glass wool [0,0040; R=16]
06   240  240  80  80  409,0  e=625
 
60  0,13  16,7  adequate  –  54(-3,-8)  6,9  77,5   awropi10b-06  
E/I = glass wool [0,0040; R=16]
07   160  160  40  40  289,0  e=625
 
60  0,18  19,0  adequate  –  53(-3,-8)  25,0  75,6   awropi10b-07  
E/I = glass wool [0,0035; R=50]
08   160  160  40  40  289,0  e=625
 
60  0,20  19,5  adequate  –  52(-3,-8)  2,2  72,5   awropi10b-08  
E/I = mineral wool [0,038; R=33]
09   160  160  40  40  289,0  e=625
 
60  0,20  19,6  adequate  –  52(-3,-8)  -7,0  76,5   awropi10b-09  
E/I = cellulose fibre [0,040; R=55]
10   160  160  40  40  289,0  e=625
 
60  0,22  20,1  adequate  –  52(-3,-8)  -9,2  69,5   awropi10b-10  
E/I = sheep wool [0,041; R=26]
11   160  160  40  40  289,0  e=400
 
60  0,21  19,5  adequate  –  52(-3,-8)  -0,7  73,7   awropi10b-11  
E/I = glass wool [0,0040; R=16]