Building components- pitched roof - sdrhzi09b-00
 
 


Cross-section of standard configuration
[Additional views]

last update12.06.2014/hfa.plb
Data sheet

pitched roof: timber frame construction, ventilated, with dry lining


Performance rating

Fire protection performance  REI 60 
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/mē
Classified by IBS
 
Thermal performance U [W/(m²K)] 0,21 
Diffusion adequate 
mw,B,A [kg/m²] 37,1 
Calculated by HFA
 
Acoustic performance Rw (C;Ctr)   53 (-2;-8)
Ln,w (Cl)  – 
with a tiled roof Rw = 51 (-2; -8) dB
Assessed by TGM
 
Sustainability* OI3Kon 6,5 
Calculated by IBO
 
   
  Register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
  concrete roof tile or tiled roof      2100     A1
 30,0 spruce wood battens (30/50)  0,130  50  500  1,600   D
 50,0 spruce wood counter battens (minimum height 50 mm)  0,130  50  500  1,600   D
 15,0 fibreboard (MDF)   0,120  11  600  1,700   D
 200,0 finger-jointed solid construction timber (80/..; e=800)  0,130  50  500  1,600   D
 200,0 glass wool [0,0040; R=16]   0,040  16  1,030   A1
 15,0 OSB (sealed with airtight tape)  0,130  200  650  1,700   D
 24,0 spruce wood cladding with spacing of cladding boards(24/100); a=400  0,130  50  500  1,600   D
 25,0 gypsum plasterboards with improved properties at high temperatures (fire) (2x12,5 mm) or  0,250  10  800  1,050   A2
 25,0 gypsum fibre board (2x12,5 mm)  0,320  21  1000  1,100   A2


* Details of sustainability rating

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-33,0 0,204 636,4 914,2 0,034 0,009


* Mass per unit area

m
[kg/m²]
calculation based on
54,6 gypsum plasterboard (DF)